Interruttore Ausiliario Abb A 145-30-11-84

0956-A145-30-11-84

Nuovo prodotto

INTERRUTTORE AUSILIARIO ABB A 145-30-11-84

225,09 €

225,09 € per PZ

INTERRUTTORE AUSILIARIO ABB Auxiliary switch A 145-30-11-84

Dimension Diagram: 53540923-7
Dimensions
Product Net Width:111.5 mm
Product Net Depth:160.0 mm
Product Net Height:196.0 mm
Product Net Weight:3.500 kg
Technical
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:1
Number of Auxiliary Contacts NC:1
Rated Operational Voltage:Main Circuit 690 V
Rated Frequency (f):Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 250 A
Rated Operational Current AC-1 (Ie):(690 V) 55 °C 230 A
(690 V) 40 °C 250 A
(1000 V) 40 °C 180 A
(1000 V) 55 °C 180 A
(690 V) 70 °C 180 A
(1000 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie):(1000 V) 55 °C 80 A
(415 V) 55 °C 145 A
(690 V) 55 °C 120 A
(220 / 230 / 240 V) 55 °C 145 A
(440 V) 55 °C 145 A
(380 / 400 V) 55 °C 145 A
(500 V) 55 °C 145 A
Rated Operational Power AC-3 (Pe):(500 V) 90 kW
(690 V) 110 kW
(220 / 230 / 240 V) 45 kW
(380 / 400 V) 75 kW
(440 V) 75 kW
(415 V) 75 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3
Short-Circuit Protective Devices:gG Type Fuses 315 A
Rated Short-time Withstand Current (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
Maximum Electrical Switching Frequency:AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
Rated Operational Current DC-1 (Ie):(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
Rated Operational Current DC-3 (Ie):(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
Rated Operational Current DC-5 (Ie):(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
Rated Insulation Voltage (Ui):acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp):Main Circuit 8 kV
Mechanical Durability:5 million
Maximum Mechanical Switching Frequency:3600 cycles per hour
Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? = 70 °C) °C
Rated Control Circuit Voltage (Uc):60 Hz 110 ... 120 V
50 Hz 110 V
Coil Consumption:Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A
Operate Time:Between Coil Energization and NO Contact Closing 13 ... 27 ms
Between Coil De-energization and NO Contact Opening 9 ... 13 ms
Between Coil De-energization and NC Contact Closing 5 ... 10 ms
Between Coil Energization and NC Contact Opening 8 ... 22 ms
Connecting Capacity Main Circuit:Rigid Al-Cable 1 x 25 ... 150 mm²
Bar 24 mm
Rigid Cu-Cable 1 x 6 ... 185 mm²
Connecting Capacity Auxiliary Circuit:Solid 1 x 1 ... 4 mm²
Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm²
Stranded 2 x 1 .... 4 mm²
Flexible 2x0.75 ... 2.5 mm²
Flexible with Ferrule 2 x 0.75 ... 2.5 mm²
Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting terminals (delivered in open position) Main poles:Flat type c/w screws and bolts
Terminal Type:Main Circuit: Bars
Environmental
Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -40 ... +70 °C
Maximum Operating Altitude Permissible:3000 m
Resistance to Shock acc. to IEC 60068-2-27:Shock Direction: A 5 g
Shock Direction: C2 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: B1 5 g
RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
Maximum Operating Voltage UL/CSA:Main Circuit 600 V
General Use Rating UL/CSA:(600 V AC) 230 A
Horsepower Rating UL/CSA:(208 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 40 Hp
Certificates and Declarations (Document Number)
BV Certificate:09826/C0 BV
CB Certificate:SE-69488
CCC Certificate:CQC_2002010304011010
Declaration of Conformity - CE:1SFA1-45
DNV Certificate:DNV_E-12191
Environmental Information:1SFC101002D0201
GL Certificate:GL_15529-00HH
Instructions and Manuals:1SFC380003-89
LOVAG Certificate:IT99055
LR Certificate:LR_12-70003
RINA Certificate:ELE060313XG/001
RMRS Certificate:RMRS_12-03683-315
RoHS Information:1SFC101046D0203

Prodotti Correlati